SKF bearings after installation, in order to check for proper installation, to running inspection, small machinery can be used to confirm the rotating hand whether rotate smoothly. Check the project caused by foreign body, scars, indentation dysfunctional, due to poor installation, rotary torque mounting process arising out of the bad, not by the clearance is too small, the installation error seal friction caused by the torque etc.. If there is no anomaly can begin power operation.
Because of the large machinery can not be manually rotated, so no load immediately after starting to turn off the power, inertial running, check whether the vibration, noise, rotating parts are in contact and so on, to confirm the into the dynamic operation without exception.
Power operation, from the no-load speed, slowly increased to the rated operating conditions. Test run of issues, whether there is abnormal sound, metastasis, SKF bearing temperature lubricant leakage and discoloration etc.. In the trial operation, if abnormal, should immediately suspend the operation, inspection machine, it is necessary to remove the bearing inspection.
Temperature check self-aligning ball bearings from the housing has speculated that. Uses of oil hole, the direct measurement of the temperature of bearing outer ring, a more accurate. SKF bearing temperature operation began to rise, without exception, stability usually 1~2 hours. If the bearing or bearing installation and other bad, the temperature will rise sharply, abnormal high temperature. The reason such as excessive lubricant, the bearing clearance is too small, poor installation, seal friction is too large. High-speed rotation of the occasion, SKF bearings lubrication method choice is also the cause of the error.